BODYSHOP
  • SPR riveters  and riveting tools for car body repair

    RIVETERS

  • Vehicle Plastic Repair Welders and Tools

    PLASTIC REPAIR

  • Dent Puller Equipment UK

    DENT REPAIR

  • Anti Static Gun for the perfect paint finish

    STATIC GUN

  • Car Body Chassis Pulling Equipment

    PULLING EQUIPMENT

  • car body panel tools for professionals

    PANEL TOOLS

  • Car body repair work trolleys and stands

    TOLLEY STANDS

  • Car body repair work trolleys and stands

    TROLLEYS STANDS

  • Car Body Measuring Tools

    MEASURING

  • Worklights and paint curing lights for car body repair

    LIGHT EQUIPMENT

  • WORKSHOP
  • GYS Battery Chargers

    BATTERY CHARGERS

  • VEHICLE DIAGNOSTICS

  • Compressor For Sale

    COMPRESSORS

  • GENERATORS

  • Pressure Washers For Sale

    PRESSURE WASHERS

  • Workshop Heaters- Diesel_Parrafinn-kerosene

    WORKSHOP HEATERS

  • PNEUMATICS

  • VEHICLE LIFTS

  • Fibrecan Spillage Absorbant

    SPILLAGE ABSORBANT

  • WELDING
  • MIG_Welding_Equipment

    MIG WELDING

  • Induction Heaters

    INDUCTION HEATERS

  • Fronius TIG Welders UK

    TIG WELDING

  • Welder Generators UK

    WELDER GENERATORS

  • Fronius Arc Welders

    ARC WELDERS

  • GAS EQUIPMENT

    GAS EQUIPMENT

  • Plasma  Cutters

    PLASMA CUTTERS

  • USED Welding Equipment For Sale

    USED EQUIPMENT

  • Spot-welders-for-car-body-repair

    SPOT WELDERS

  • Welding Wires For Sale

    WELDING WIRES

  • TOOLS
  • AIR Tools For Bodyshop and Workshop

    AIR TOOLS

  • Cordless Tools

    CORDLESS TOOLS

  • TorAnd Calibration Servicesque Wrenches

    TORQUE WRENCHES

  • Abrasives for Bodywork

    ABRASIVES

  • TENG Tool Boxes

    TOOL BOXES

  • EV TOOLS

  • Screwdriver Sets

    SCREWDRIVERS

  • DRILLS BURRS

  • Panel Hammers and Panel Hammer sets

    PANEL HAMMERS

  • SAFETY
  • WELDING HELMETS

  • Dust Extraction for workshops and bodyshops

    DUST EXTRACTION

  • Welders Clothes and apparel

    WELDERS CLOTHES

  • Work Gloves and hand safety protection

    WORK GLOVES

  • WELDING CURTAINS

  • Safety Visors

    VISORS AND EYEWEAR

  • FUME EXTRACTION

  • RESPIRATORY HELMETS

  • Welding Blankets

    WELDING BLANKETS

  • November 13, 2021 3 min read

    This is one of the most common questions we get asked and its important especially when it comes to Inverter welders and possible site work what size generator will I need?.

    When hiring or using a generator you will often be asked "what size Do you Need?" Generator sizes are measured in kilovolt-amperes (kVA) and its important that you get the correct size to run your equipment as damage to both your inverter and your generator can occur if you select wrongly.

    what generator size do I need?

    WHAT IS KVA?

    kVA is the "Apparent" power or how much power you can work with.

    WHAT IS KWA?

    Kilowatt is the "Actual" power a system has ie the actual usable output.

    If kW is how much power you can work with, kVA tells you how much is being used.

    Generators are always measured in kVA

    POWER FACTOR

    If an electrical circuit was perfectly efficient  then a kW would be equal to a kVA. But because no system is completely efficient, not all of the apparent power will be converted into useful output. There will be losses. We therefore need to take these losses into consideration when working out.  This is what we call "power factor" and in general generators have a power factor of 0.8

    formula converting kW to Kva

    CONVERTING KVA TO KWA

    To convert kW to kVA, you first need to know the efficiency (or power factor) of the system. Power factor (pf) is measured on a scale from 0 to 1.

    On average, a generator will have a power factor of 0.8.

     kW to kVA is     
     kW / Power factor
    kVA to kW kVA x PF

     

    Example kW to kVA:

    100kW divided by power factor 0.8 = 80kVA

    Example kVA to kW:

    100kVA times  Power Factor 0.8 = 80kW

     

     inside an inverter welder

    WHAT IS VOLT DROP?

    This is the important part in this and the reason its critical in selecting a generator large enough to run your equipment.

    Inverters are a parallel system if you ask for a lot of current out (welding) then it will require it to draw more current in (supply) to feed this.  

    If the current you ask for in welding cannot be supplied fast enough by the supply then you will experience a volts drop in the circuit and this in turn means more current could flow causing current (amps) to rise even further until either the supply trips or the internals of the inverter blow.

    This is why this fluctuation is dangerous to inverters, these peaks and troughs of you arcing up and down causes voltage fluctuations in the inverter and this can prove fatal if its allowed too much.

     

    Ive tried to use inverter spot welders before on an inverter and actually managed to nearly stop the generator from turning due to the load I put on it. This I found quite scary and I wouldn't recommend you try it.

    Spot welder specification plate

    LOOK AT THE SPECIFICATION PLATE

    Some but not all manufacturers put the kVA required on the specification plate.

    The example above is for a spot welder which we normally wouldn't recommend use on a generator, but as you can see its a 400v welder and at 50% power (S50) it requires a 17kVA generator. 

    WHAT IF IT DOESN'T SHOW kVA?

    We need to do some more maths to work this one out. to work out the "watts" we need to use:

    Watts= Volts x Amps.

     230x25= 5750

    or 5.7kW

    Convert to kVA

    kW ÷ Pf    

    5750 ÷ 0.8 = 11.5KVA

    You would need an 11.5 kVA generator to run this welder at full power.

     

    kW to kVA CONVERSION CHART

     kW kVA
    5 6.3
    7.5 9.3
    10 12.5
    15 18.720
    20 25
    25 31.3

     

     What does duty cycle mean on a welder

     

     

     

     

     

     

     

     

    Leave a comment